Mitsubishi Electric Melservo-J3 Series MR-J3-B Instruction Manual page 51

Melservo j3 series general-purpose ac servo sscnet compatible
Hide thumbs Also See for Melservo-J3 Series MR-J3-B:
Table of Contents

Advertisement

2. INSTALLATION
(b) Installation of two or more servo amplifiers
Leave a large clearance between the top of the servo amplifier and the internal surface of the control box,
and install a cooling fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
When installing the servo amplifiers closely, leave a clearance of 1mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
In this case, bring the ambient temperature within 0 to 45 , or use it at 75% or smaller effective load ratio.
30mm
or more
Leaving clearance
(2) 11k to 22kW
(a) Installation of one servo amplifier
Control box
40mm or more
Servo amplifier
10mm
or more
POINT
Mounting closely is available for a combination of servo amplifiers of 3.5kW or
less in 200V or 100V class.
Control box
100mm
or more
10mm
or more
40mm
or more
10mm
or more
120mm
or more
30mm
30mm
or more
or more
Control box
Wiring allowance
80mm
2 - 2
Control box
100mm
or more
1mm
1mm
40mm or more
Mounting closely
Top
Bottom
30mm
or more