Mitsubishi Electric Melservo-J3 Series MR-J3-B Instruction Manual page 240

Melservo j3 series general-purpose ac servo sscnet compatible
Hide thumbs Also See for Melservo-J3 Series MR-J3-B:
Table of Contents

Advertisement

11. OPTIONS AND AUXILIARY EQUIPMENT
(b) When connecting two brake units to a servo amplifier
POINT
To use brake units with a parallel connection, use two sets of FR-BU2 brake
unit. Combination with other brake unit results in alarm occurrence or
malfunction.
Always connect the master and slave terminals (MSG and SD) of the two
brake units.
Do not connect the servo amplifier and brake units as below. Connect the
cables with a terminal block to distribute as indicated in this section.
Servo amplifier
P ( )
N ( )
Connecting two cables to
P and N terminals
Brake unit
P/
N/
Brake unit
P/
N/
11 - 37
Servo amplifier
Brake unit
P ( )
P/
N ( )
N/
Brake unit
P/
N/
Passing wiring

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents