Software Upgrade and Boot Options
Table 53: Image version fields (Continued)
Field
Description
patch
Identifies a specific patch release.
build
Specifies the ExtremeWare XOS build number. This value is reset to zero for each new
major and minor release.

Software Signatures

Each ExtremeWare XOS image contains a unique signature. The BootROM checks for signature
compatibility and denies an incompatible software upgrade. In addition, the software checks both the
installed BootROM and software and also denies an incompatible upgrade.

Rebooting the Switch

To reboot the switch, use the following command:
reboot {time <month> <day> <year> <hour> <min> <sec> | cancel}
Use this command to schedule a time to reboot the switch or to reboot the switch immediately. To
schedule a time to reboot the switch, use the following command:
reboot time <date> <time>
Where
is the date and
date
rebooted. The values use the following format:
mm dd yyyy hh mm ss
NOTE
When you configure a timed reboot of the switch, use the
To reboot the switch immediately, use the following command:
reboot
If you do not specify a reboot time, the reboot occurs immediately following the command, and any
previously schedule reboots are cancelled. To cancel a previously scheduled reboot, use the
option.

Rebooting the Management Module

To reboot a management module in a specific slot, rather than rebooting the switch, use the following
command:
reboot {time <month> <day> <year> <hour> <min> <sec> | cancel}
with the additional options available:
— Specifies the slot where the module is installed
slot number
—Specifies the MSM module installed in slot A
msm-a
—Specifies the MSM module installed in slot B
msm-b
ExtremeWare XOS 11.1 Concepts Guide
is the time (using a 24-hour clock format) when the switch will be
time
show switch
{msm <slot_id>}
command to see the scheduled time.
{msm <slot_id>}
cancel