Fully Redundant Vrrp Network - Extreme Networks ExtremeWare XOS Guide Manual

Concepts guide
Hide thumbs Also See for ExtremeWare XOS Guide:
Table of Contents

Advertisement

Virtual Router Redundancy Protocol
physical interface. Each physical interface on each backup router must have a unique IP address. The
virtual router IP address is also used as the default gateway address for each host on the network.
If the master router fails, the backup router assumes forwarding responsibility for traffic addressed to
the virtual router MAC address. However, because the IP address associated with the master router is
not physically located on the backup router, the backup router cannot reply to TCP/IP messages (such
as pings) sent to the virtual router.

Fully Redundant VRRP Network

You can use two or more VRRP-enabled switches to provide a fully redundant VRRP configuration on
your network.
Figure 52
Figure 52: Fully redundant VRRP configuration
Switch A
Master for virtual IP 192.168.1.3
Master VRID = 1
Backup for virtual IP 192.168.1.5
Backup VRID = 2
MAC address = 00-00-5E-00-01-01
Default Route
In
Figure
52, switch A is configured as follows:
IP address 192.168.1.3
Master router for VRID 1
Backup router for VRID 2
MAC address 00-00-5E-00-01-01
Switch B is configured as follows:
IP address 192.168.1.5
Master router for VRID 2
Backup router for VRID 1
MAC address 00-00-5E-00-01-02
Both virtual routers are simultaneously operational. The traffic load from the four hosts is split between
them. Host 1 and host 2 are configured to use VRID 1 on switch A as their default gateway. Host 3 and
host 4 are configured to use VRID 2 on switch B as their default gateway. In the event that either switch
fails, the backup router configured is standing by to resume normal operation.
ExtremeWare XOS 11.1 Concepts Guide
shows a fully redundant VRRP configuration.
Backup Route
Switch B
Master for virtual IP 192.168.1.5
Master VRID = 2
Backup for virtual IP 192.168.1.3
Backup VRID = 1
MAC address = 00-00-5E-00-01-02
EX_069
360

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.1

Table of Contents