Displaying Port Poe Information - Extreme Networks ExtremeWare XOS Guide Manual

Concepts guide
Hide thumbs Also See for ExtremeWare XOS Guide:
Table of Contents

Advertisement

Total ports faulted—Displays the number of ports in a fault state.
Total ports disabled—Displays the number of ports in a disabled state.
Following is sample output from this command:
Inline-Power Slot Statistics
Slot:
3
Firmware status
Firmware revision
Total ports powered
Total ports awaiting power
Total ports faulted
Total ports disabled

Displaying Port PoE Information

You can display PoE configuration, status, and statistics per port.
Displaying Port PoE Configuration
Use the following command to display PoE configuration for each port:
show inline-power configuration ports <port_list>
This command provides the following information:
Config—Indicates whether the port is enabled to provide inline power:
Enabled: The port can provide inline power.
Disabled: The port cannot provide inline power.
Operator Limit—Displays the configured limit, in milliwatts, for inline power on the port.
Priority—Displays inline power priority of the port, which is used to determine which ports get
power when there is insufficient power for all ports requesting power:
Low
High
Critical
Label—Displays a text string, if any, associated with the port (15 characters maximum).
Following is sample output from this command:
Port
Config
Operator Limit
3:1
Enabled
15000 mW
3:2
Enabled
15000 mW
3:3
Enabled
15000 mW
3:4
Enabled
15000 mW
3:5
Enabled
15000 mW
3:6
Enabled
15000 mW
3:7
Enabled
15000 mW
3:8
Enabled
15000 mW
3:9
Enabled
15000 mW
3:10
Enabled
15000 mW
ExtremeWare XOS 11.1 Concepts Guide
: Operational
: 292b1
: 17
: 31
: 0
: 0
Priority
Label
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Displaying PoE Settings and Statistics
117

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.1

Table of Contents