Extreme Networks ExtremeWare XOS Guide Manual page 125

Concepts guide
Hide thumbs Also See for ExtremeWare XOS Guide:
Table of Contents

Advertisement

MSM LED Behavior—BlackDiamond 10K Switch
Table 16
describes the BlackDiamond MSM LED behavior during a diagnostic test.
Table 16: BlackDiamond 10K switch MSM LED behavior
LED
Color
SYS
Green blinking
Amber blinking
Amber
While diagnostic tests are running, the SYS LED blinks amber. If a diagnostic test fails, the SYS LED
goes to solid amber. After the MSM completes the diagnostic test, or the diagnostic test is terminated,
the SYS LED is reset. During normal operation, the status LED blinks green.
I/O Module LED Behavior—BlackDiamond 10K Switch
Table 17
describes the BlackDiamond I/O module LED behavior during a diagnostic test.
Table 17: BlackDiamond 10K switch I/O module LED behavior
LED
Color
DIAG
Off
Amber blinking
Amber
Status
Green blinking
Amber blinking
While diagnostic tests are running, the DIAG LED blinks amber. If a diagnostic test fails, the DIAG LED
goes to solid amber and the Status LED blinks amber. After the I/O module completes the diagnostic
test, or the diagnostic test is terminated, the DIAG and the Status LEDs are reset. During normal
operation, the DIAG LED is off and the Status LED blinks green.
MSM LED Behavior—Aspen 8810 Switch
Table 18
describes the Aspen MSM LED behavior during a diagnostic test.
Table 18: Aspen 8810 switch MSM LED behavior
LED
Color
SYS
Green blinking
Amber blinking
Amber
STAT
Amber
While diagnostic tests are running, the STAT LED blinks amber. If a diagnostic test fails, the SYS LED
and the STAT LED go to solid amber. After the MSM completes the diagnostic test, or the diagnostic test
is terminated, the STAT LED is reset. If you start another diagnostic test, the STAT LED blinks amber.
During normal operation, the status LED blinks green.
ExtremeWare XOS 11.1 Concepts Guide
Indicates
Normal operation is occurring.
Diagnostic test in progress.
Diagnostic failure has occurred.
Indicates
Normal operation is occurring.
Diagnostic test in progress.
Diagnostic failure has occurred.
Normal operation is occurring.
Configuration error, code version error, diagnostic failure, or other severe
module error.
Indicates
Normal operation is occurring.
Diagnostic test in progress.
Diagnostic failure has occurred.
Progress of the diagnostic test.
Slot Diagnostics
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.1

Table of Contents