Sfp-Class Threshold Defaults - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric watch v3.1.x/4.1.x user guide (aa-rtsgc-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Default Threshold Values
Table 33
Table 33: SFP-Class Threshold Defaults
Area
Description
Temperature
Monitors SFP(s)
Temperature in
Celsius
Receive Power
Monitors
receive power
in µwatts
Transmit Power
Monitors
transmit power
in µwatts
Current
Monitors SFP
current in
mamps
Supply Voltage
Measures the
amount of
supplied
voltage to the
SFP
214
provides default settings for areas in the SFP class.
Default Threshold
Settings
Unit: C
Time Base:
Low: -10
High: 85
Buffer: 3
Unit: µWatts
Time Base:
Low: 0
High: 5000
Buffer: 25
Unit: µWatts
Time Base:
Low: 0
High: 5000
Buffer: 25
Unit: mA
Time Base:
Low: 0
High: 50
Buffer: 1
Unit: mV
Time Base:
Low: 3150
High: 3600
Buffer: 10
Default Alarm
Settings
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 1
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Fabric Watch Version 3.1.x/4.1.x User Guide
Threshold
State
Informative
Faulty
Faulty
Faulty
Normal
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Faulty
Normal
Informative

Advertisement

Table of Contents
loading

Table of Contents