Performance Monitor-Class Areas; Fru-Class Areas - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric watch v3.1.x/4.1.x user guide (aa-rtsgc-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Using Fabric Watch
Table 7
description of each area.
Table 7: Performance Monitor-Class Areas
invalid CRCs
receive
performance
transmit
performance
customer define
Table 8
each area.
Table 8: FRU-Class Areas
slot
36
lists Fabric Watch areas in the performance monitor classes and provides a
Area
Errors have been detected in the FC frame. Invalid CRC
messages occur when the number of CRC errors in fibre
channel frames for specific source ID (SID) and destination ID
(DID) pairs change. These messages may also be caused by
dirty equipment, temperature fluctuations, and aging
equipment.
Receive performance messages appear due to the number of
word frames that travel from the configured SID to the DID
pair. User configuration triggers these messages. Use the
receive performance area to tune your network.
Transmit performance messages appear due to the number of
word frames that travel from the configured SID to the DID
pair. User configuration triggers these messages. Use the
transmit performance area to tune your network.
The customer define area relies on performance monitor telnet
commands. For more information on this area, refer to the
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference
Guide
Monitoring Version 3.1.x/4.1.x User Guide
lists Fabric Watch areas in the FRU class and provides a description of
Area
Description
HP StorageWorks Advanced Performance
and the
Description
Indicates that the state of a slot has changed to one of
the following:
absent
faulty
inserted
on
off
ready
up
Fabric Watch Version 3.1.x/4.1.x User Guide