Responding to Fabric Watch Messages
Troubleshooting
Message
Description
Troubleshooting
Message
Description
Troubleshooting
162
All filter area messages are informational. Respond to this message as is
appropriate to the particular policy of the end-user installation.
FW-EXCEEDED, 3, filterPerfPT<element index> (FILTER Filter Counter
<element index>) is exceeded boundary. current value : <value> Frame(s).
(info)
Explains that the number of frame types or commands that the port receives
has risen above or fallen below the acceptable range. Provides the new
value.
All filter area messages are informational. Respond to this message as is
appropriate to the particular policy of the end-user installation.
FW-INBETWEEN, 3, filterPerfPT<element index> (FILTER Filter Counter
<element index>) is between high & low boundaries. current value :
<value> Frame(s). (info)
Explains that the number of frame types or commands that the port receives
has changed from a value outside of the acceptable range to a value within
the acceptable range. Provides the new value.
All filter area messages are informational. Respond to this message as is
appropriate to the particular policy of the end-user installation.