Default Threshold Values
Table 23
Table 23: Port-Class Threshold Defaults
Area
Description
Link failure
Monitors number
count
of Link failures
Loss of
Monitors number
synchronizati
of loss of
on count
synchronization
errors
Loss of signal
Monitors number
count
of signal loss
errors
Primitive
Monitors number
sequence
of primitive
protocol error
sequence protocol
errors
Invalid
Monitors the
transmission
number of invalid
word
words transmitted
Invalid CRC
Monitors the
count
number of CRC
errors
200
provides default settings for areas in the Port class.
Default Threshold
Settings
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 120
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 120
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Default Alarm
Settings
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Fabric Watch Version 3.1.x/4.1.x User Guide
Threshold
State
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative