SAN Switch 2/32 Threshold Defaults

Table 32
Table 32: Environment-Class Threshold Defaults
Area
Temperature
Monitors switch
temperature in
Celsius
Fan
Monitors switch
fan speed in
RPMs
Power Supply
Monitors power
supply
condition
Fabric Watch Version 3.1.x/4.1.x User Guide
provides default settings for areas in the Environment class.
Default Threshold
Description
Unit: C
Time Base:
Low: 0
High: 67
Buffer: 10
Unit: RPM
Time Base:
Low: 2600
High: 10,000
Buffer: 3
Unit: 1OK/0FAULTY
Time Base:
Low: 1
High: 0
Buffer: 0
Default Alarm
Settings
Changed: 0
Exceeded: 0
Below: 3
Above: 3
In-between: 3
Changed: 0
Exceeded: 0
Above: 3
Below: 3
In-between: 1
Changed: 0
Exceeded: 0
Below: 3
Above: 3
In-between: 0
Default Threshold Values
Threshold
Settings
Informative
Faulty
Faulty
Faulty
Normal
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Faulty
Normal
Informative
State