Table 34
Table 34: Port-Class Threshold Defaults
Area
Link failure
Monitors
count
number of Link
failures
Loss of
Monitors
synchronization
number of loss
count
of
synchronization
errors
Loss of signal
Monitors
count
number of
signal loss
errors
Primitive
Monitors
sequence
number of
protocol error
primitive
sequence
protocol errors
Invalid
Monitors the
transmission
number of
word
invalid words
transmitted
Invalid CRC
Monitors the
count
number of CRC
errors
Fabric Watch Version 3.1.x/4.1.x User Guide
provides default settings for areas in the Port class.
Default Threshold
Description
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 120
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 120
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Unit: Error(s)
Time Base: minute
Low: 1
High: 60
Buffer: 0
Default Alarm
Settings
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Changed: 0
Exceeded: 0
Below: 1
Above: 1
In-between: 0
Default Threshold Values
Threshold
Settings
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Normal
Faulty
Informative
State
215