Fabric Watch Version 3.1.x/4.1.x User Guide
This is an informational message. Respond to this message as is appropriate
to the particular policy of the end-user installation.
FW-BELOW, 3, sfpVolt<element index> (Sfp Voltage <element index>) is
below low boundary, current value: <value> mV. (faulty)
Explains that the SFP voltage value has fallen below the low boundary.
Provides the new value.
Configure the low threshold to 1 so that the threshold triggers an alarm when
the value falls to 0 (Faulty). If continuous or repeated alarms occur, replace
the SFP before it deteriorates.
FW-ABOVE, 3, sfpVolt<element index> (Sfp Voltage <element index>) is
above high boundary, current value: <value> mV. (faulty)
Explains that the SFP voltage value has risen above the high boundary.
Provides the new value.
This is an informational message. Respond to this message as is appropriate
to the particular policy of the end-user installation.
FW-INBETWEEN, 3, sfpVolt<element index> (Sfp Voltage <element
index>) is between high and low boundaries, current value: <value> mV.
(normal)
Explains that the SFP voltage value has changed from a value outside of the
acceptable range to a value within the acceptable range. Provides the new
value.
This is an informational message. Respond to this message as is appropriate
to the particular policy of the end-user installation.
Responding to Fabric Watch Messages
125