Default Threshold Values
Core Switch 2/64 Threshold Defaults
Table 21
Table 21: Environment-Class Threshold Defaults
Temperature
Fan
Power Supply
198
provides default settings for areas in the Environment class.
Area
Description
Monitors
switch
temperature
in Celsius
Monitors
switch fan
speed in
RPMs
Monitors
power supply
condition
Default
Threshold
Default Alarm
Settings
Unit: C
Changed: 0
Time Base:
Exceeded: 0
Low: 0
Below: 3
High: 75
Above: 3
Buffer: 10
In-between: 3
Unit: RPM
Changed: 0
Time Base:
Exceeded: 0
Low: 2000
Above: 3
High: 3400
Below: 3
Buffer: 3
In-between: 1
Unit:
Changed: 0
1OK/0FAULTY
Exceeded: 0
Time Base:
Below: 3
Low: 1
Above: 3
High: 0
In-between: 0
Buffer: 0
Fabric Watch Version 3.1.x/4.1.x User Guide
Threshold
Settings
State
Informative
Faulty
Faulty
Faulty
Normal
Informative
Informative
Normal
Faulty
Informative
Informative
Informative
Faulty
Normal
Informative