Replacing The Disks; Status Showing Multiple Disk Failure; Raid Showing Two Disk Failures; Devices Page Awaiting Raid Initialization - HP StorageWorks D2D100 - Backup System User Manual

Hp storageworks d2d backup system (hp d2d2503) user guide (eh990-90905, december 2008)
Hide thumbs Also See for StorageWorks D2D100 - Backup System:
Table of Contents

Advertisement

Figure 73 Status showing multiple disk failure
The device operating system is not stored on any of the disks, so the HP D2D Backup System is still
usable after replacing the failed disks. Use the Web Management Interface or the System Console
to help you identify the disks that have failed.
Figure 74 RAID showing two disk failures

Replacing the disks

Power off and replace the disks, as described earlier in this chapter. When you power on again,
the RAID will not rebuild automatically. The Summary page continues to show the RAID System as
catastrophically failed. If you look at the Devices or Cartridges page, no information is available other
than that the library is awaiting RAID initialization.
Figure 75 Devices page awaiting RAID initialization
If you have the System Console connected you will see Fault conditions for System Status and RAID Status
and that the RAID is not mounted, even though the disks are shown as OK.
170
Hard disk replacement

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks d2d2503

Table of Contents