For countries outside of Europe, you must use a power cord set
■
that complies with the relevant national standards for cable type
and appliance coupling.
Table 6 Regulatory Requirements
Country or Region Power Cord Set Details
Europe
■
■
United Kingdom
■
■
Italy
■
■
Denmark
■
Switzerland
■
The appliance coupler (that is, the connector to the unit, not the
■
connector to the wall plug) must have a configuration that mates with
an EN60320/IEC320 appliance inlet.
The socket outlet must be near the unit and easily accessible. You can
■
remove power from the unit only by disconnecting the power cord
from the outlet. If your SuperStack 3 NBX Call Processor has
redundant power supplies, you must disconnect both cords from the
wall.
This unit operates under SELV (Safety Extra Low Voltage) conditions
■
according to IEC 60950. These conditions are maintained only if the
equipment to which the unit is connected also operates under SELV
conditions.
France only:
■
This unit cannot be powered from IT (Impédance à la Terre) supplies. If
your supplies are of IT type, this unit must be powered by 230V (2P+T)
via an isolation transformer ratio 1:1, with the secondary connection
point labelled Neutral, connected directly to earth (ground).
When this system is used in Australia, you must connect the equipment
to the telephone network via a line-isolating unit (LIU) that complies with
ACA TS001-1997.
Important Safety Information
The supply plug must comply with CEE 7/7 ("SCHUKO")
The main cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
The supply plug must comply with BS1363 (3-pin 13 A)
and be fitted with a 5A fuse that complies with BS1362.
The main cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
The supply plug must comply with CEI23-16/VII.
The main cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.