78
C
2: I
HAPTER
NSTALLING
Configuring NBX
System Networking
S
H
C
YSTEM
ARDWARE
OMPONENTS
Table 9 SS3 NBX Disk LED States (continued)
Explanation
Flash codes indicate disk problem:
2 flashes: No valid disk (system is halted)
■
3 flashes: Two valid disks, but they are not
■
paired (system is halted)
4 flashes: Configuration problem (system is
■
halted)
5 flashes: Two disks present, but no
■
mirroring license
Using disk 0 (zero) only
Using disk 1 only
Synchronizing — disk 0 is valid, disk 1 is
becoming a fully mirrored disk. LED 3 flash rate
indicates progress.
If LED 3 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
Synchronizing — disk 1 is valid, disk 0 is
becoming a fully mirrored disk. LED 2 flash rate
indicates progress.
If LED 2 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
LED 2 and LED 3 flash alternately: the two disks
are resynchronizing
Synchronized
You are now ready to establish network/LAN Connectivity. See
"Configuring NBX System Networking"
Configuring the networking for the NBX system involves these steps:
Establishing IP Connectivity
■
Modifying Default IP Settings
■
Establishing LAN Connections
■
Configuring IP Addresses for Your LAN
■
LED 1
LED 2
N/A
Flashing Flashing
N/A
On
N/A
Off
N/A
On
Flashing
N/A
Flashing
N/A
Flashing Flashing
N/A
On
next.
LED 3
PWR
On
Off
On
On
On
On
On
On
On
On
On
Need help?
Do you have a question about the 3C10111C - NBX 100 - Modular Exp Base and is the answer not in the manual?