5024-001
5. When the last digit is changed, press Select to validate the
Configuration ID.
If the ID is invalid then "INVALID ID" message displays on
Line 2 before the ID re-displays. You have to reenter the
configuration ID until a valid ID is verified.
If the ID is valid then the ID is saved in NVRAM and the
printer automatically PORs to activate the new setting.
Note: When the printer PORs it does so in the normal mode.

Parallel Strobe Adjustment

This setting lets the user adjust the factory setting for the amount of
time strobe is sampled. This determines whether valid data is
available on the parallel port.
Increasing this value means that strobe is sampled 50ns longer.
Decreasing this value means that strobe is sampled 50ns shorter.
The range of this setting is -4 to +6.
Example of setting:
A value of 0 indicates no adjustment is sampled from the factory
setting.
A value of -1 indicates the sample strobe time is reduced by
50ns.
A value of +3 indicates the sampled strobe time is increased by
150ns.