5024-001
Color Misregistration Service Check
Color misregistration between two colors.
FRU
1
OPC Belt Cartridge
2
OPC Belt Cartridge
3
Cleaning Brush
4
Drum Cleaner Brush
Action
OPC belt cartridge is not properly
installed.
Reset the OPC belt cartridge.
OPC belt cartridge is deformed.
Replace the OPC belt cartridge.
Cleaning brush is unstable during
operation.
Replace the cleaning brush.
OPC belt cartridge rotation load is
excessive.
Replace the drum cleaner brush.
Diagnostic Information
2-87