5024-001

Resetting Counters

Resetting maintenance and supply counters are required after
replacing the following parts during service.
– Transfer drum
– Maintenance kit
– Fuser
– Fuser cleaner
– Photo developer cartridge
Any other supplies can be reset in the operator supplies menu.
To reset an individual counter:
1. Select reset counters from the diagnostic mode menu.
2. Select the counter to be reset from the menu.
A message, with the individual counter on the first line, is
displayed.
The second line displays (=Reset).
3. Press Select.
A message is displayed stating that the individual counter has
been reset.
The next counter is displayed with the resetting of an individual
counter.

Error Log

Viewing the Error Log

The error log provides a history of printer errors. The error log
contains the 12 most recent errors that have occurred on the printer.
The most recent error displays in position 1 and the oldest error
displays in position 12 (if 12 errors have occurred). If an error occurs
after the log is full, the oldest error is discarded. Identical errors in
consecutive positions in the log are entered. All 2xx and 9xx error
messages are stored in the error log.