5024-001
Lower Feeder Unit Paper Size Sensor (SL-PS -A57
P.W.B. Assembly) Removal
1. Remove the LFU base cover (L). See
Base Cover (L) Removal" on page
2. Remove the harness connector to the paper size sensor.
3. Remove the set screws BT3X8 (2) from the LFU cassette
guide (L).
4. Pull the LFU cassette guide (L) toward you.
5. Remove the set screws BT3X8 (2) from the paper size
sensor.
6. Remove the paper size sensor.
"Lower Feeder Unit
4-99, for more information.
Repair Information
4-101