5024-001
Drum Jam Sensor (DPJ) Removal
1. Remove the fuser unit.
2. Remove the OPC belt cartridge.
3. Remove the drum cleaner.
4. Remove the transfer drum. See
page
4-81, for more information.
5. Remove the wiring harness cover Ex and cover F.
6. Disconnect the drum jam sensor.
7. Remove the drum jam sensor from the stay B.
4-68
Service Manual
"Transfer Drum Removal" on