5024-001
Residual Image Service Check
Image of the preceding page appears on every other page.
FRU
1
Cleaning Brush
2
Drum Cleaner
3
High Voltage Unit
2-94
Service Manual
Action
Cleaning brush failure.
Ensure proper installation of the
drum cleaner.
Drum cleaner bias pole contact
failure. Clean or replace.
DC high voltage unit failure.