Static Wep Rules; Ieee 802.1X; Table 24:  Ieee 802.1X - D-Link DWL-3600AP Administrator's Manual

Unified wired & wireless access system
Hide thumbs Also See for DWL-3600AP:
Table of Contents

Advertisement

Unified Access Point Administrator's Guide
Static WEP Rules
If you use Static WEP, the following rules apply:
• All client stations must have the Wireless LAN (WLAN) security set to WEP, and all clients must have one of 
the WEP keys specified on the AP in order to de‐code AP‐to‐station data transmissions.
• The AP must have all keys used by clients for station‐to‐AP transmit so that it can de‐code the station 
transmissions.
• The same key must occupy the same slot on all nodes (AP and clients). For example if the AP defines 
abc123 key as WEP key 3, then the client stations must define that same string as WEP key 3.
• Client stations can use different keys to transmit data to the access point. (Or they can all use the same 
key, but this is less secure because it means one station can decrypt the data being sent by another.)
• On some wireless client software, you can configure multiple WEP keys and define a client station 
"transfer key index", and then set the stations to encrypt the data they transmit using different keys. This 
ensures that neighboring APs cannot decode each other's transmissions.
• You cannot mix 64‐bit and 128‐bit WEP keys between the access point and its client stations.
IEEE 802.1X
IEEE 802.1X is the standard defining port‐based authentication and infrastructure for doing key management. 
Extensible Authentication Protocol (EAP) messages sent over an IEEE 802.11 wireless network using a protocol 
called EAP Encapsulation Over LANs (EAPOL). IEEE 802.1X provides dynamically‐generated keys that are 
periodically refreshed. An RC4 stream cipher is used to encrypt the frame body and cyclic redundancy checking 
(CRC) of each 802.11 frame.
This mode requires the use of an external RADIUS server to authenticate users. The AP requires a RADIUS 
server capable of EAP, such as the Microsoft Internet Authentication Server. To work with Windows clients, the 
authentication server must support Protected EAP (PEAP) and MSCHAP V2.
You can use any of a variety of authentication methods that the IEEE 802.1X mode supports, including 
certificates, Kerberos, and public key authentication. You must configure the client stations to use the same 
authentication method the AP uses.
Field
Description
Use Global RADIUS 
By default each VAP uses the global RADIUS settings that you define for the AP at the top 
Server Settings
of the VAP page. However, you can configure each VAP to use a different set of RADIUS 
servers. 
To use the global RADIUS server settings, make sure the check box is selected. 
To use a separate RADIUS server for the VAP, clear the check box and enter the RADIUS 
server IP address and key in the following fields.
RADIUS IP Address 
Specify the IP version that the RADIUS server uses.
Type
You can toggle between the address types to configure IPv4 and IPv6 global RADIUS 
address settings, but the AP contacts only the RADIUS server or servers for the address 
type you select in this field.