Failure Detection Pair Configuration; Link To Monitor Configuration - HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Command Reference Manual

Hp 1:10gb ethernet bl-c switch for c-class bladesystem command reference guide
Hide thumbs Also See for 438031-B21 - 1:10Gb Ethernet BL-c Switch:
Table of Contents

Advertisement

Table 178
Uplink Failure Detection Configuration Menu options
Command
off
cur

Failure Detection Pair configuration

Command: /cfg/ufd/fdp
[FDP Menu]
Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM) and
one Link to Disable (LtD). When the switch detects a failure on the LtM, it automatically disables the ports
in the LtD.
The following table describes the Failure Detection Pair (FDP) Configuration Menu options.
Table 179
Failure Detection Pair Configuration Menu options
Command
ltm
ltd
ena
dis
current

Link to Monitor configuration

Command: /cfg/ufd/fdp/ltm
[Failure Link to Monitor Menu]
Description
Globally turns Uplink Failure Detection OFF.
Displays the current Uplink Failure Detection configuration parameters.
ltm
- Link to Monitor Menu
ltd
- Link to Disable Menu
ena
- Enable FDP
dis
- Disable FDP
current - Display current FDP configuration
Description
Displays the Links to Monitor menu.
Displays the Links to Disable menu.
Enables the FDP Parameters.
Disables the FDP Parameters.
Displays the current FDP configuration.
addport - Add port to Link to Monitor
remport - Remove port from Link to Monitor
addtrnk - Add trunk to Link to Monitor
remtrnk - Remove trunk from Link to Monitor
addkey
- Add adminkey to Link to Monitor
remkey
- Remove adminkey from Link to Monitor
cur
- Display current LtM configuration
Configuration Menu
187

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents