Uplink Failure Detection configuration

Command: /cfg/ufd
[Uplink Failure Detection Menu]
Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use this
menu to configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to
Disable (LtD) group. When UFD is enabled and a Failure Detection Pair is configured, the switch
automatically disables ports in the LtD if it detects a failure in the LtM. The failure conditions which are
monitored in the LtM group include port link state moving to down, or port state moving to Blocking if
Spanning Tree Protocol is enabled.
The following table describes the Uplink Failure Detection (UFD) Configuration Menu options.
Table 188
Uplink Failure Detection Configuration Menu options
Command
fdp
on
off
cur

Failure Detection Pair configuration

Command: /cfg/ufd/fdp
[FDP Menu]
Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM)
and one Link to Disable (LtD). When the switch detects a failure on the LtM, it automatically disables
the ports in the LtD.
The following table describes the Failure Detection Pair (FDP) Configuration Menu options.
Table 189
Failure Detection Pair Configuration Menu options
Command
ltm
ltd
ena
dis
fdp - Failure Detection Pair Menu
on
- Globally turn Uplink Failure Detection ON
off - Globally turn Uplink Failure Detection OFF
cur - Display current Uplink Failure Detection configuration
Description
Displays the Failure Detection Pair menu.
Globally turns Uplink Failure Detection ON.
Globally turns Uplink Failure Detection OFF.
Displays the current Uplink Failure Detection configuration parameters.
ltm
- Link to Monitor Menu
ltd
- Link to Disable Menu
ena
- Enable FDP
dis
- Disable FDP
current - Display current FDP configuration
Description
Displays the Links to Monitor menu.
Displays the Links to Disable menu.
Enables the FDP Parameters.
Disables the FDP Parameters.