07 Non-HP switch at other end of the ISL. The cable is
connected to a non-HP switch and interop mode is set to Homogeneous fabric
mode.
•
08 ISL connection not allowed on this port. The port type
configuration does not match the actual port use (the port is configured as an
F_Port, but attaches to a Edge Switch or Director).
•
10 Port binding violation - unauthorized WWN. The WWN
entered to configure port binding is not valid or a nickname was used that is not
configured through the Product Manager for the attached device.
•
11 Unresponsive node connected to port. Possible causes are:
— Hardware problem on switch or on a connected node where ELP frames are
not delivered, the response is not received, or a fabric login in (FLOGI) cannot
be received. There may be problems in switch SBAR.
— Faulty or dirty cable connection.
— Faulty host bus adapters that do not send out FLOGI within reasonable
timeframe.
Segmented E_Port Messages:
•
Incompatible operating parameters, such as resource allocation time-out values
(R_A_TOV) or error-detect time-out values (E_D_TOV) are inconsistent. Refer to
Configure Fabric Operating Parameters on page 3–6
•
Duplicate domain IDs. Refer to
3–6
for more information.
•
Incompatible zoning configurations. Refer to sections on joining zoned fabrics in
the hp StorageWorks edge switch 2/24 service manual and the hp StorageWorks
ha-fabric manager user guide for details.
•
Build fabric protocol error.
•
No principal switch (no switch in fabric is capable of being principal switch).
•
No response from an attached switch.
edge switch 2/24 product manager user guide
Monitoring and Managing the Switch
Configure Fabric Operating Parameters on page
for more information.
2–11