Assembling The Outer Rails (Hp System/E Rack); Screws Required To Assemble The Inner Rails - HP 1606 Hardware Reference Manual

Hp storageworks 8-gb san switch hardware reference guide (5697-0291, july 2010)
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

• For an HP System/e Rack, install two #10-32 x 1/2-inch Phillips panhead screws with
captive star lock washers and two #10 alignment washers in the upper and lower holes
on the right rail. Then, install two #10-32 x 1/2-inch Phillips panhead screws with captive
star lock washers and two #10 alignment washers in the upper and lower holes on the
left rail. (See
Figure 18 Assembling the outer rails (HP System/e rack)
.
5.
See
Table 6
to determine the screw type and the number of screws required for your device.
CAUTION:
Use only the screws that have been provided. Using longer screws can cause damage to
internal components.
Table 6 Screws required to assemble the inner rails
Device
8/8 SAN Switch
8/24 SAN Switch
8/40 SAN Switch
8/80 SAN Switch
Encryption SAN Switch
FCoE Converged Network Switch
1606 Extension SAN Switch
6.
Identify the screw holes to attach the inner rails to your device:
• To attach the inner rails to the 8/8 or 8/24 SAN Switches, use the five screw holes marked
8. The plenum requires one screw hole marked 8 and one screw hole marked 16, as shown
in
Figure 21
on page 42.
• To attach the inner rails to the 8/40 or 8/80 SAN Switches, use the screw holes marked 16,
as shown in
Figure 20
• To attach the inner rails to the FCoE Converged Network Switch, Encryption SAN Switch, or
1606 Extension SAN Switch, use two screw holes marked R and one screw hole marked 16.
40
Installing and configuring an 8-Gb SAN Switch
Figure
18.)
#8-32 x 5/16-inch
screws
Ten (five per rail)
Six (three per rail)
on page 41.
#8-32 x 3/16-inch
screws
N/A
N/A