Download Print this page

HP 1606 Hardware Reference Manual Page 65

Hp storageworks 8-gb san switch hardware reference guide (5697-0291, july 2010).
Hide thumbs

Advertisement

LED name
LED color
Slow flashing green
(on 1 second, then
off 1 second)
Fast flashing green
(on 1/4 second,
then off 1/4 second)
Flickering green
Steady amber
Very slow flashing
amber (on 2
seconds, than off 2
seconds)
Fast flashing amber
(on 1/2 second,
then off 1/2 second)
Power supply
No light
status
Steady green
Steady amber (for
more than 5
seconds)
Status of hardware
Port is online, but segmented
because of a loopback cable or
incompatible switch connection.
Port is online and an internal
loopback diagnostic test is run-
ning.
Port is online and frames are
flowing through the port.
Port is receiving light or signal
carrier, but is not online yet.
Port is disabled because of dia-
gnostics or the portdisable
command.
SFP or port is faulty.
Indicates one of the following:
Power supply FRU is
switched off.
Power supply FRU is not
seated correctly.
Power cord is disconnected.
Power cord is not actively
powered.
The power supply FRU has
failed.
Power supply is operating nor-
mally.
Indicates one of the following:
Power supply FRU is
switched off.
Power supply FRU is not
seated correctly.
The power cable is discon-
nected.
The power supply FRU has
failed.
NOTE:
When the switch is first
powered on, the power supply
status LED shows amber until
POST has completed.
8-Gb SAN Switch Hardware Reference Guide
Recommended action
Verify that the correct device is at-
tached to the switch.
No action required.
No action required.
No action required.
Verify that the diagnostic tests are
not running. Re-enable the port us-
ing the portenable command.
Replace the SFP.
Reset the port.
Do the following:
Verify that the power supply
FRU is powered on.
Verify that the power supply
FRU is seated correctly.
Check the power cable connec-
tion.
Replace the power supply FRU.
No action required.
Do one of the following:
Verify that the power supply
FRU is powered on.
Verify that the power supply
FRU is seated correctly.
Check the power cable connec-
tion.
Replace the power supply FRU.