LED name
Fan status

Port side LED activity for the FCoE Converged Network Switch

Figure 31
shows the port side of the FCoE Converged Network Switch. There are two port status LEDs
above each of the top row of ports. The left LED is for the top port, and the right LED is for the bottom
port. See
Figure 7
1. System power LED
2. System status LED
3. Ethernet speed LED
.
Table 11
describes the port side LEDs and the recommended actions.
66
Managing the 8-Gb SAN Switches
LED color
Status of hardware
No light
Indicates one of the following:
Fan FRU is not seated cor-
rectly.
Fan FRU is not receiving
power.
Steady green
Fan assembly is operating nor-
mally.
Steady amber (for
Indicates one of the following:
more than 5
Fan FRU is not seated cor-
seconds)
rectly.
One or more of the fans in
the fan FRU has failed.
The fan FRU was disabled
by the user.
NOTE:
When the switch is first
powered on, the fan status
LED shows amber until POST
has completed.
on page 21 for the locations of the GbE and FC ports.
Figure 31 Port side LEDs on the FCoE Converged Network Switch
Recommended action
Do one of the following:
Verify that the fan FRU is
seated correctly.
Verify that the switch is
powered on.
No action required.
Do one of the following:
Verify that the fan FRU is
seated correctly.
Verify that the fan FRU is en-
abled (use the fanenable
command).
Replace the fan FRU.
4. Ethernet link LED
5. CEE port status LED (port 0)
6. CEE port status LED (port 4)