Fan Assembly Leds; Replacing The 8/40 San Switch Power Supply And Fan Assembly; Fan Status Led Behavior, Description, And Required Actions - HP 1606 Hardware Reference Manual

Hp storageworks 8-gb san switch hardware reference guide (5697-0291, july 2010)
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

Fan assembly LEDs

Table 15
describes the fan status LED colors, behaviors, and actions required, if any.
Table 15 Fan status LED behavior, description, and required actions
LED color and behavi-
or
No light
Steady green
Steady amber (for more
than five seconds)

Replacing the 8/40 SAN Switch power supply and fan assembly

CAUTION:
Disassembling any part of the power supply and fan assembly voids the warranty and regulatory
certifications. There are no user-serviceable parts inside the power supply and fan assembly. Because
the cooling system relies on pressurized air, do not leave any of the fan assembly slots empty longer
than two minutes while the switch is operating. If a fan assembly fails, leave it in the switch until it
can be replaced. Maintain all fan assemblies in operational condition to provide redundancy.
Replacing the power supply and fan assembly unit takes approximately two minutes. You will need:
New power supply and fan assembly FRU (one unit)
Phillips-head screwdriver #1
To replace the power supply and fan assembly unit:
1.
Use a Phillips-head screwdriver to unscrew the captive screw on the power supply fan assembly
you are replacing.
2.
Remove the power supply fan assembly you are replacing from the chassis by pulling the handle
out and away from the chassis.
3.
Install the new power supply fan assembly unit in the chassis:
a.
Orient the new fan assembly with the captive screw on the right.
b.
Gently push the power supply fan assembly into the chassis until it is firmly seated.
CAUTION:
Do not force the installation. If the power supply fan assembly does not slide in easily,
ensure that it is correctly oriented before continuing.
c.
Secure the fan assembly to the chassis by screwing in the captive screw.
Description
Fan assembly is not receiving power.
Fan assembly is operating normally.
Fan fault for one of the following
reasons:
One or more of the fans in the fan
assembly has failed.
The fan FRU was disabled by the
user.
8-Gb SAN Switch Hardware Reference Guide
Action required
Verify that the fan FRU is seated correctly.
No action required.
Verify that the fan FRU is enabled. If the
fan FRU is enabled and the FRU is faulty
it should be replaced.
77