en | Default Configuration
6.2.1

General Camera Settings

Video and audio connections menu > Camera section > Edit button
Make the settings for each camera as required.
1
2
3
4
5
6
7
F.01U.033.308 | V7 | 2009.09
General settings
Name:
Video loss
Bilinx settings
Image properties
AGC
(AGC = automatic gain
control)
Gain:
Installation Guide
Click the tab.
Enter the name of the camera. The name must not contain
any special characters or end with a space.
Activate this check box if a warning should be shown on
camera signal failure.
Note:
The malfunction relay is also activated if a relay output is
selected as a malfunction relay in the configuration (Inputs
and outputs menu, Relay tab).
Click the button to access the Bilinx camera navigation menu.
The Bilinx camera menu is displayed in the image window.
Note:
Only selectable for Bilinx-capable cameras.
Set brightness, contrast, color and hue. You can see the
result of these settings in the camera image (Hue is only
active on NTSC cameras).
Activate this check box if the camera signal on the grabber
should be amplified.
Manually correct the input level audio level at the grabber
using the slider.
Note:
Only possible when AGC is not activated.
DiBos/DiBos Micro