● NEW: New
AUX/MOD
○ Accum Rev : Gate destination. When the gate is low, stages accumulate as programmed.
When the gate is high, stages will play the pitches calculated by the accumulator in the
reverse order. This differs from Accum Invert, which inverts the
TRANSPOSE AMOUNTS (causing the accumulation to recalculate).
○ Accum Mode : Gate destination. When the gate is high, the programmed accumulation
Mode ("Stage" or "Track," as set on the LIM screen) will toggle to the other option; and
be restored to the programmed value when the gate is low.
○ Accum Polar : Gate destination. When the gate is high, the programmed accumulation
Polarity ("Unipolar" or "Bipolar," as set on the LIM screen) will toggle to the other option;
and be restored to the programmed value when the gate is low.
● NEW: 14 chord shapes (7 Major and 7 Minor) have been added to the end of the
which confine notes to a particular chord shape, rather than a scale. These can be particularly
useful (and melodic) when used in conjunction with Metropolix' accumulator feature.
● NEW: Added a Clock Mode function in the
(and an expander) outputs clock signals only while the sequencer is running
(Clock Mode = Running), or if it outputs clocks even when the sequencer is stopped
(Clock Mode = Always). NOTE: In v1.4, the name was changed to Clk/Rset Out.
● NEW: Added a Run Btn function in the
when the RUN button is pressed. In both cases, if the sequencer is not running, pressing RUN
will start the sequencer. The difference is in what happens when you press the RUN button to
stop a running sequence. If set to Run/Pause, pressing the RUN button pauses playback, but
does not reset the sequencer — meaning a subsequent press of the RUN button will start the
sequencer from its current position, and not from the beginning. If set to Run/Stop, pressing the
RUN button stops playback and resets the sequencer to the beginning.
● NEW: "Panic" button: Press the RESET button when Metropolix is not running to set
Track 1 & 2's GATE outputs to 0V.
● CHANGE: Updated menus with new visual features: disabled items; dividers.
● CHANGE: Pitch offset modulation is applied when a track is muted, but it will continue to ignore
updates to the modulation when a track is muted.
● CHANGE: When EDIT is active, the selected STAGE number button will blink — in both Track
and MOD views.
● FIX: Fixed Mod Lane resets on queued Preset loads.
● FIX: Crash when RUN goes low before a queued preset loads.
destinations:
SETUP
SETUP
Metropolix Manual
MENU, which determines whether Metropolix
MENU, which sets how Metropolix behaves
ACCUM
screen's
Scales
list,
200

Advertisement

loading
Need help?

Need help?

Do you have a question about the Metropolix and is the answer not in the manual?

This manual is also suitable for:

Metropolix solo