Calibrating Metropolix Inputs
You can calibrate all three of Metropolix' variable inputs (X, Y, and Z) using the same technique.To
Calibrate Metropolix' inputs:
TIP: If you make a mistake at any point during the following calibration procedure, you can scroll to
the bottom of the Calibration menu, select Reload All, and press the encoder. This will reload the
current, previously saved values back into Metropolix. Once you enact a Save All, this is no longer
possible, since your edited values will overwrite the previous calibration.
To Calibrate Metropolix' Inputs:
1.
Enter Calibration Mode, as discussed above.
2.
Prior to calibrating Metropolix' inputs, you must calibrate its outputs using the technique
discussed above.
Calibrated outputs are a necessity, since they will be used as the reference source for
calibrating Metropolix' inputs.
3.
Patch Metropolix' calibrated OUT A jack into Metropolix' X input jack
Although this example uses OUT A as a reference source, you can use any of the four
calibrated outputs: TRK 1 PITCH, TRK 2 PITCH, OUT A or OUT B.
NOTE: The positions of the X, Y, and Z attenuverters are ignored while calibrating.
4.
Turn the encoder to highlight 'Aux X: [number] / [number]', then press the encoder.
Input X is automatically calibrated upon pressing the encoder.
5.
Move one end of the patch cable to the Y input; turn the encoder to highlight 'Aux Y: [number] /
[number]', then press the encoder.
Input Y is automatically calibrated upon pressing the encoder.
6.
Move one end of the patch cable to the Z input; turn the encoder to highlight 'Aux Z: [number] /
[number]', then press the encoder.
Input Z is automatically calibrated upon pressing the encoder.
To Save the Calibration:
1.
Turn the encoder to select 'Save All', then press the encoder to save your calibration.
Metropolix Manual
187