● OUTPUT ASSIGN : This parameter displays the Track number (or MOD Lane) whose signal is
sent to the A (or B) OUT jack. It is set by 1) pressing the encoder to move the
to the OUTPUT ASSIGN parameter (activating it), then 2) rotating the encoder to set the source
of the signal, then 3) pressing the encoder to apply your selection.
○ If OUTPUT <n> is assigned to 'Ctrl <n>' or 'Run', this parameter is global, and no
OUTPUT ASSIGN settings are available.
○ If OUTPUT <n> is assigned to 'Mod', this parameter selects which of the eight MOD
Lanes is the output source.
○ If OUTPUT <n> is assigned to a source other than 'Ctrl <n>', 'Run' or 'Mod', this
parameter selects which of the two Tracks is the output source.
NOTE: If you assign the Trk Out Swap parameter to a
then any Track Assignments will "swap" when a high gate initiates the Track Out Swap feature.
For example, if you assigned a TRK 1 parameter to OUT A and TRK 2 parameter to OUT B,
then Trk Out Swap would "swap" the assignments, such that the TRK 1 parameter is sent to OUT
B; and the TRK 2 parameter is sent to OUT A.
CTRL knob
Metropolix Manual
indicator next
or an
AUX input or MOD
Lane,
117