Download Print this page

Intellijel Metropolix Manual page 19

Multitrack, performance-oriented pitch, gate and mod sequencer
Hide thumbs Also See for Metropolix:

Advertisement

OUTPUTS
[A]
A OUT - The first of two user assignable signals is sent out this jack. To assign a signal to this
jack, press the ALT button to enter ALT mode, then press the
described in
OUT A &
The color of the output LED changes depending on the type of signal it carries
(blue
= pitch/root data;
[B]
B OUT - The second of two user assignable signals is sent out this jack. To assign a signal to
this jack, press the ALT button to enter ALT mode, then press the
described in
OUT A &
corresponding LED indicates the type of signal assigned to it.
[C]
CLOCK OUT - Outputs a clock from Metropolix. A clock signal is output only when the
sequencer is running. The output clock can run at any division of the input (whether internally
or externally clocked), as set by the Clk Div parameter accessed via the ALT +
(Stage 5) button, as discussed in CLK, later in this manual.
[D]
TRACK 1 PITCH OUT - By default, the 1 V/Oct pitch generated by Track 1 is sent out this
jack. However, it's possible to swap Track assignments, such that Track 2's pitch is sent to this
jack. This feature (called Trk Out Swap) can be assigned to a
MOD
Lane.
[E]
TRACK 1 GATE OUT - By default, Track 1's gate signal (off = 0V; on = +5V) is sent out this
jack. However, like with the PITCH out, you can swap it to carry Track 2's gate output instead.
The corresponding LED lights whenever the gate output is high (on).
[F]
TRACK 2 PITCH OUT - By default, the 1 V/Oct pitch generated by Track 2 is sent out this
jack. However, it's possible to swap Track assignments, such that Track 1's pitch is sent to this
jack. This feature (called Trk Out Swap) can be assigned to a
MOD
Lane.
[G]
TRACK 2 GATE OUT - By default, Track 2's gate signal (off = 0V; on = +5V) is sent out this
jack. However, like with the PITCH output, you can swap it to carry Track 1's gate output
instead. The corresponding LED lights whenever the gate output is high (on).
B, later in this manual.
yellow
= gate/trigger;
B, later in this manual. As with the A output, the color of its
Metropolix Manual
A
(Stage 3) button, as
green
(+) /
red
(-) = continuous voltage).
B
CTRL knob
CTRL knob
(Stage 4) button, as
CLK
or an
AUX input or
or an
AUX input or
18

Advertisement

loading
Need help?

Need help?

Do you have a question about the Metropolix and is the answer not in the manual?

This manual is also suitable for:

Metropolix solo