Removing The Library From The Rack - Quantum PX500 Series User Manual

Quantum px500: user guide
Hide thumbs Also See for PX500 Series:
Table of Contents

Advertisement

Removing the Library from the Rack

Quantum PX500 Series User's Guide
To remove the PX502 library from the rack:
1 Using the OCP, open the front doors, remove both tape cartridge
magazines, and remove any tape cartridges from the fixed bins or
FlexLink™ (refer to
information on OCP operation and bin locations).
You must remove all tape cartridges from the library prior
Note:
to parking the library robotics for shipment.
After removing the tape cartridge magazines and closing the doors,
the library inventories all possible tape cartridge locations
(magazines, fixed slots, Flexlink, and tape drives). This process takes
several minutes.
2 From the
Library Operations
. The library shuts down automatically.
Shipping
3 From the back of the library, disconnect all power, Ethernet, and SCSI
cables from the library and note their locations for later reinstallation.
Warning:
This unit has more than one power supply cord.
Disconnect all power supply cords before servicing to
avoid electric shock.
4 To remove the library chassis from the rack (see
a Loosen the captive screws securing the tape drives to the chassis
and remove the tape drive(s) from the back of the library.
Loosen the captive screw securing the power supplies to the
b
chassis and remove the power supplies from the back of the
library.
c
Remove PHILLIPS screws securing each side of the chassis to the
rack mounting rails and remove two Allen screws securing both
clamps on the back of the library.
d
Remove the library from the rack.
Appendix D Repacking the PX502 Library
Removing the Library from the Rack
chapter 2, Basic Library Operations
screen on the OCP, select
for
Park for
figure
125):
230

Advertisement

Table of Contents
loading

This manual is also suitable for:

Px502Px506Px510

Table of Contents