Event Detail
XY-position fail
XY-safe to rotate fail
Y-position fail (zone #)
Bad SCSI Sense Data
Aborted any open
exchanges
ADT login failed
Bad reply received
Login failed, too many
retries
Login failed, no response
Unexpected login, not
handled or requested
ACI invalid Response
Command Id not
supported
Could not send adt
logout
Message Id not
supported
Quantum PX500 Series User's Guide
Event Description
The robotic hand has failed to
position the XY axis to a
predetermined physical location.
The safe to rotate sensor used to
home the XY axis could not be
seen by the calibration routine.
The robotic hand has failed to
position the XY axis to a
predetermined physical location.
A command sent to the drive
received bad sense data.
Drive communications has failed.
The library failed to login and set
up communication to a drive.
The drive did not return a valid
response.
The library could not initiate
communications with the drive.
Drive did not respond correctly to
the login command sequence.
The drive unexpectedly sent a
login request.
The HP Gen 2 Drive returned an
invalid command response.
This command is not supported
by the drive.
Drive communications (possibly
due to hardware) is lost.
Command is not supported by the
drive.
Chapter 4 SNMP Trap List
Category
Reported By
Critical
Diagnostics
Warning
Diagnostics
Critical
Diagnostics
Warning
Drive
Manager
Informational
Drive
Manager
Critical
Drive
Manager
Warning
Drive
Manager
Warning
Drive
Manager
Warning
Drive
Manager
Informational
Drive
Manager
Warning
Drive
Critical
Manager
Critical
Drive
Manager
Critical
Drive
Manager
Critical
Drive
Manager