Load Port Configuration; Table 17 Import/Export Option Settings - Quantum PX500 Series User Manual

Quantum px500: user guide
Hide thumbs Also See for PX500 Series:
Table of Contents

Advertisement

Load Port Configuration

Table 17 Import/Export Option
Settings
Quantum PX500 Series User's Guide
Load ports are used to import or export tape cartridges from the library.
When configured as a load port, your backup application will
automatically use these bins when exporting or importing tape
cartridges. The bottom left and right magazines in each library can be
configured to provide the following load port elements:
• Single column load port (5 slots SDLT/6 slots LTO)
• Magazine load port (15 slots SDLT/18 Slots LTO)
Deciding between a single column and an entire
Tech Tip:
magazines as a load port depends on the amount of tape
cartridges you typically import/export from the library. If
you generally import or export small numbers of tape
cartridges to and from the library, a single column should
be sufficient. If you import or export large numbers of
tape cartridges, an entire magazine as a load port would
be beneficial.
Each of the load ports are configured independently so that one load port
can be configured as a column and the other load port can be configured
as a column or as a magazine.
When set for a single column load port, the magazine is physically
restricted to allow access to the first column in the magazine only.
When set for a 15-slot load port, the entire magazine can be removed (the
same for a 18-slot LTO magazine).
The load port option is set using the operator control panel
The settings are listed in
Setting
None
Single column
Magazine
Chapter 2 Basic Library Operations
table 17
and illustrated in
Manual Access
None
Single column
Entire magazine
Load Port Configuration
menu.
Setup
figure
58.
SCSI Element
Storage element
Import/Export element
Import/Export element
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Px502Px506Px510

Table of Contents