1000 Series HT - Installation Guide
Installation Guide
Water Connection (1000 Series HT
1. Locate the built-in stainless steel booster on the left-side of the dishwasher.
The existing hot water supply lines to the dishwasher must be 3/4" NPT or larger. To the best of
your ability inspect, and verify that all supply piping meets the 3/4" NPT requirement.
The installing plumber must connect a water supply line to the dishwasher that is equal to or
greater than 3/4" NPT in size and a 3/4" pressure regulating valve, PRV, (not supplied).
Dishwasher temperature
and water pressure requirements:
140°F/60°C minimum for 40° F/22° C rise booster
(35 psi/241 KPa static pressure)
7-10 psi/48-69Kpa flow pressure
110°F/43°C minimum for 70° F/39° C rise booster
(35 psi/241 KPa static pressure)
7-10 psi/48-69Kpa flow pressure
2. Connect a 3/4" NPT hot water supply to the dishwasher at the line strainer.
)
Note:
Note: