Installation Guide | iC7 Series Liquid-cooled System Modules
Table 27: Source DC- Fuses for DC/DC Converter, Voltage Classes B5 and 07, IP00/Open Type (continued)
(1)
Model code
iC7-60SLDCxx-2880E00F4
iC7-60SLDCxx-3240E00F4
iC7-60SLDCxx-3600E00F4
1) xx = B5 or 07
Danfoss Drives Oy © 2024.03
Frame
Rated
Number
current
of fuses
(I
) [A]
L
3 x DR12L
2880
6
3240
6
3600
6
Fuse
Part number
size
(Mersen)
73
PC73UD13C800TF
73
PC73UD12C900TF
AN389643231588en-000101 / 172F6360A |
Fuse U
Fuse I
I
n
n
cp, mr
[V]
[A]
[A]
1250
800
8900
1200
900
10200