Chapter 10 — Troubleshooting
96
EasyCoder PF2i Bar Code Label Printer User's Guide (Fingerprint Version)
Note 4: This error indicates that the printer has not received an IP
address. It is only applicable for printers with IP SELECTION set to
DHCP and/or BOOTP.
Note 5: In the Direct Protocol, the user can enable error handling for
specific errors using the ERROR statement. When errors added to the
built-in error handling occur, this event will be set. The text included in
the snmp trap is the standard text corresponding to the error.
Note 6: If an error occurs in the Fingerprint immediate mode, for
example "out of paper" when the print key is pressed, this event will be
set.
Note 7: If an application is started but does not execute, the IRI will
blink. This will occur for example if there is a syntax error in the loaded
program file. This is useful when a printer has an AUTOEXEC.BAT file
(startup file) that is supposed to run automatically.
Note 8: When execution is stopped with user break (SHIFT + PAUSE)
or due to a run-time error, the IRI shall be off. It will be set to on if the
user changes mode to Direct Protocol or runs an application. If,
however, the application program handles the user break (ON BREAK)
or the runtime error (ON ERROR GOTO), the IRI will not be affected.
In this case, it is up to the application to set the status.
Note 9: At most, but not all, printer crashes, the console is reset. This
will make the IRI go off.