Rs-232 Interface - Intermec EasyCoder PF2i User Manual

Bar code label printer (fingerprint version)
Hide thumbs Also See for EasyCoder PF2i:
Table of Contents

Advertisement

Appendix C — Interfaces

RS-232 Interface

144
EasyCoder PF2i Bar Code Label Printer User's Guide (Fingerprint Version)
Protocol
Default setup:
Baud rate: 9600
Character length: 8 bits
Parity: None
Stop bits: 1
RTS/CTS: Disabled
ENQ/ACK: Disabled
XON/XOFF: Disabled (both ways)
New Line: CR/LF
To change the RS-232 interface settings, see
Printer" on page 49.
Signals on Printer's Serial Port "uart1:"
DB-9
Signal
Meaning
1
External =5V DC
2
TXD
Transmit data
3
RXD
Receive data
4
DSR
Data set ready
5
GND
Ground
6
DTR
Data terminal ready
7
CTS
Clear to send
8
RTS
Request to send
9
Not used
The external +5V is limited to 500 mA and is
*
automatically switched off at overload.
"Setting Up the
*

Advertisement

Table of Contents
loading

Table of Contents