When freezing risk is detected and filtration started, the pump CANNOT be stopped until the temperature
detected is higher than the protection setting, or the Protection Antifreeze is switched OFF in the Pool
Filtration Reduction When Pool Cover is Detected Closed
To be effective, this functionality assumes the connection of Pool Cover, or mobile floor limit switch to a PoolCop input. (see 5.6.4).
Depending on if pool is configured with a single or multi-speed pump, reduction strategy is different:
5.6.1.5.1 Filtration Time Reduction (Single Speed Pump)
Select the reduction percentage you want to apply to the filtration duration (Apply
only to
ECO+
mode) when the cover is closed.
5.6.1.5.2 Pump Speed Reduction (Variable or Multi Speed Pump)
Select the desired pump speed (apply to every filtration mode) when the cover is
closed. This speed will replace the normal Cycle 1 or Cycle 2 preselected speeds as
long as the cover is closed.
If value is 0, no change will occur when the cover state changes.
Pool Type
Selecting the type of pool automatically configures some functions:
SKIMMER
– the valve reverts to a "safe" Filter position whenever filtration is
inactive. Water level control is standard.
OVERF.A
– (Overflow) the valve reverts to a "safe" Filter position whenever
filtration is inactive. Water level control is adapted to suit an infinity pool.
OVERF.B
– (Overflow) the valve reverts to a "safe" Closed position (to prevent
the pool draining into the buffer tank with the pump OFF) whenever filtration
is inactive. Water level control is adapted to suit an infinity pool.
SPA
– the valve reverts to a "safe" Filter position whenever filtration or other
functions are inactive, and there is no volume correction in ECO mode.
Changing the Pool Type affects the way that water level control functions. Be sure to read and fully
The freezing risk alerts are always active, even with freezing protection OFF.
Multispeed pumps are started on speed #1 supposedly the lowest speed.
understand the implications prior to changing this setting.
P o o l C o p E v o l u t i o n M a n u a l : E V 4 4 M A N U S
NOTE:
Data menu.
NOTE:
NOTE:
NOTE:
Text:
Cover Reduc
Default:
30%
Entries:
0% to 70%
Text:
Cover speed
Default:
0
Entries:
0 to 8
Text:
Pool type
Default:
Skimmer
Entries:
Skimmer;
OverF.A;
OverF.B;
Spa