Specifying The Severity Level - Alcatel-Lucent OmniSwitch 6850-48 Network Configuration Manual

Software release 6
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

Switch Logging Commands Overview
CLI Keyword
EPILOGUE
LDAP
NOSNMP
SSL
DBGGW
LANPOWER
The level keyword assigns the error-type severity level to the specified application IDs. Values range from
2 (highest severity) to 9 (lowest severity). The values are defined in the following table:
Severity Level
2 (highest severity)
3
4
5
6 (default)
7
8
9 (lowest severity)

Specifying the Severity Level

To specify the switch logging severity level, use the
be expressed by using either the ID number or the application ID CLI keyword as listed in the table begin-
ning on
page
46-6. The severity level can be expressed by using either the severity level number or the
severity level type as shown in the table above. The following syntax assigns the "warning" severity level
(or 5) to the "system" application, (ID number 75) by using the severity level and application names.
-> swlog appid system level warning
The following command makes the same assignment by using the severity level and application numbers.
-> swlog appid 75 level 3
No confirmation message appears on the screen for either command.
page 46-8
Numeric
Application ID
Equivalent
85
APPID_EPILOGUE
86
APPID_LDAP
87
APPID_NOSNMP
88
APPID_SSL
89
APPID_DBGGW
108
APPID_LANPOWER
Type
Alarm
Error
Alert
Warning
Info
Debug 1
Debug 2
Debug 3
swlog appid level
OmniSwitch AOS Release 6 Network Configuration Guide
Description
A serious, non-recoverable error has occurred
and the system should be rebooted.
System functionality is reduced.
A violation has occurred.
An unexpected, non-critical event has occurred.
Any other non-debug message.
A normal event debug message.
A debug-specific message.
A maximum verbosity debug message.
command. The application ID can
Using Switch Logging
September 2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents