sFlow Overview

Quick Steps for Configuring sFlow

Follow the steps below to create a sFlow receiver session.
1
To create a sFlow receiver session, use the
receiver, followed by the receiver index, name, and the address to be monitored. For example:
-> sflow receiver 1 name Golden address 198.206.181.3
2
Optional. Configure optional parameters. For example, to specify the timeout value "65535" for sFlow
receiver session on address 198.206.181.3, enter:
-> sflow receiver 1 name Golden address 198.206.181.3 timeout 65535
Note. Optional. To verify the sFlow receiver configuration, enter
sFlow receiver index. The display is similar to the one shown below:
-> show sflow receiver
Receiver 1
Name
= Golden
Address
= IP_V4 198.206.181.3
UDP Port
= 6343
Timeout
= 65535
Packet Size= 1400
DatagramVer= 5
For more information about this command, see
in the OmniSwitch CLI Reference Guide.
Follow the steps below to create a sFlow sampler session.
1
To create a sFlow sampler session, use the
sampler, followed by the instance ID, port list, receiver, and the rate. For example:
-> sflow sampler 1 2/1-5 receiver 1 rate 2048
2
Optional. Configure optional parameters. For example, to specify the sample-hdr-size value "128" for
sFlow sampler instance 1 on ports 2/1-5, enter:
-> sflow sampler 1 2/1-5 receiver 1 rate 2048 sample-hdr-size 128
Note. Optional. To verify the sFlow sampler configuration, enter
sFlow sampler instance ID. The display is similar to the one shown below:
-> show sflow sampler 1
Instance
Interface
-----------------------------------------------------------------
1
2/ 1
1
2/ 2
1
2/ 3
1
2/ 4
1
2/ 5
page 45-8
sflow agent
"sFlow" on page 45-29
sflow sampler
Receiver
Sample-rate
1
2048
1
2048
1
2048
1
2048
1
2048
OmniSwitch AOS Release 6 Network Configuration Guide
Diagnosing Switch Problems
command by entering sflow
show sflow
receiver, followed by the
or the "sFlow Commands" chapter
command by entering sflow
show sflow
sampler, followed by the
Sample-hdr-size
128
128
128
128
128
September 2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents