Handling the ENABLE Signal
Set how the ENABLE signal is handled.
Note
ENABLE signal
The ENABLE signal is a control signal for indicating that the ZFX-C is ready to accept a measurement trigger or a
command from an external device. External devices monitor the ON/OFF timing of this ENABLE signal to input the
measurement trigger or commands to the ZFX.
Operation when the TRIG signal is input during measurement
Next measurement is not executed even if the TRIG signal from an external device is input during
measurement. Set whether or not to notify an external device that TRIG signal input was not accepted.
MENU mode - [System] - [Measure] - [Trig in measure]
Setting value
OFF
ERR ON
Operation Conditions during Startup
Set the bank data to be displayed when the Controller is started up.
MENU mode - [System] - [Startup]
Setup Item
Startup Bank Group
Startup Bank
Setting/Changing the Display Language
Set the display language of the LCD screen.
MENU mode - [System] - [Language]
Setting value
Japanese
English
122
System Settings
Description
The ERR signal does not turn ON even if the TRIG signal turns ON during measurement.
The ERR signal turns ON when the TRIG signal turns ON during measurement. (default
value)
The ERR signal turns OFF when the next TRIG signal is input at the correct timing.
Description
Sets the bank group No. to be displayed when the Controller is started up. (default value: 0)
When bank groups 1 to 31 are selected, start up the Controller with the SD card contain-
ing the corresponding bank data attached.
Sets the bank No. to be displayed when the Controller is started up.
Range: 0 to 31 (default value: 0)
Description
UI text in the LCD screen and menus is displayed in Japanese.
UI text in the LCD screen and menus is displayed in English.
ZFX-C User's Manual