Setup Item
Coordinates mode
• Split size, Edge level, Noise level, Noise width p.62
• Coordinates mode p.63
Note
Measurement mode
When Maximum and Minimum are selected, the measurement region is split up into small regions by Split size to
calculate the edge width. The maximum value or the minimum value is output. When Average is selected, the aver-
age of the entire measurement region is calculated.
66
Setting Measurement Items
Setting value
Description
Normal (default value)
The position information of the input image coordinate system
itself is output.
Pos. correction
When position shift correction is set, the position information is
output using the coordinate system corrected to the original
state when the coordinate system was registered.
Width when [Maximum] is selected
Start point
Width when [Minimum] is selected
Split size
End point
ZFX-C User's Manual