Connecting Devices - Omron ZFX-C10 User Manual

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Connecting Devices

Connecting the Controller to the Power Supply
Use a power supply that meets the following specifications.
Item
Power supply voltage
Output current
Recommended power supply
Recommended electric wire size
Important
Use a DC power supply with countermeasures against high voltages (safe extra low-voltage circuits on the secondary
side). If the system must meet UL standards, use a UL class II power supply.
+
24 VDC
Attaching Ferrite Cores
Attach ferrite cores (supplied) to both ends of the camera's cable and the Controller's power cable, respectively.
Ferrite core
Ferrite core
28
Mounting and Connecting Devices
Specification
Approx. 24 VDC (21.6 to 26.4 VDC)
1.0 A min.
S8VS-06024 (24 VDC, 2.5 A)
0.14 to 1.5 mm
-
-
+
2
(max. 1 m)
1
Loosen the two screws on the top of the Power con-
nector (male) using a flat-blade screwdriver.
2
Insert the DC power terminal (wire) into the Power
connector (male) and tighten the two screws on the
top of the Power connector to fasten the power termi-
nal with the screwdriver.
Tightening torque: 0.22 to 0.25 N•m.
3
Plug the Power connector (male) into the Controller's
Power connector (female).
4
Tighten the two screws on the left and right of the Power
connector (male) with the screwdriver to fasten it.
Tightening torque: 0.22 to 0.25 N•m.
Ferrte core
When attaching ferrite cores to the Controller's power
cable, pass the cable once through each ferrite core.
DC power
supply
ZFX-C User's Manual

Advertisement

Table of Contents
loading

Table of Contents