Omron ZFX-C10 User Manual page 59

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Detailed settings (if necessary)
When measurement is not stable, adjust the detailed conditions.
MENU mode - [Setup] - [Item] - [Detail]
Setup Item
Setting value
Measure axis angle
OFF (default value)
ON
Fill profile
OFF (default value)
ON
Calibration
OFF (default value)
ON
Coordinates mode
Normal
(default value)
Pos. correction
Coordinates mode p.63
ZFX-C User's Manual
Description
Sets whether or not to measure the axis angle. When [ON] is selected, the process-
ing time increases proportionately to the time it takes to measure the axis angle.
To measure the outer periphery of the measurement target, set this item to [ON].
When this item is set to [ON], measurement is performed with all of the
area between the start point (colors outside of measurement target →
measurement target color) and the end point (measurement target
color → colors outside of measurement target) inside the measurement
region judged to the measurement target color.
Start point
End point
When the measurement target color is overlaps the measurement region
Input image (Fill profile: OFF)
Pixels that are measurement target color are not recognized as the start point
as pixels that are colors outside of measurement target are next scanned.
When measuring the measurement target with unevenness
The measurement result changes according to the direction in
which the measurement target is fed.
Input image (Fill profile: OFF)
Measurement results are output using the camera's coordinate values.
Measurement results are output using the coordinate value converted by the
calibration function.
The position information of the input image coordinate system itself
is output.
When position shift correction is set, the position information is out-
put using the coordinate system corrected to the original state
when the coordinate system was registered.
Measurement
region
Fill profile: ON
Fill profile: ON
Fill profile: ON
Setting Measurement Items